NO REGISTRATION, just download...
Listed below are the common Ariston fault codes as described by the boiler manufacturer along with a possible cause.
Fault Code | Boiler Model | Possible Cause |
---|---|---|
Central Heating Circuit | ||
101 | All Boilers | Overheat |
102 | E-Combi Evo E-System Evo Clas He Evo (Combi and system) |
Pressure sensor error |
103 | All Boilers | Insufficient circulation |
104 | All Boilers | Insufficient circulation |
105 | All Boilers | Insufficient circulation |
106 | All Boilers | Insufficient circulation |
107 | All Boilers | Insufficient circulation |
108 | All Combi Boilers | Insufficient water (request filling) |
109 | Clas net one / Clas one Combi Clas system one |
System pressure greater than 3 bar |
110 | All Boilers | Central heating Flow temperature probe circuit open / short circuit |
112 | All Boilers | Central heating return temperature probe circuit open / short circuit |
114 | All Boilers | External sensor circuit open / short circuit |
116 | All Combi and System Boilers | Floor thermostat contact open |
118 | All Boilers | Heating delivery probe problem |
1p1 | All Boilers | Insufficient circulation indication |
1p2 | All Boilers | Insufficient circulation indication |
1p3 | All Boilers | Insufficient circulation indication |
1p4 | Clas Net one Combi Clas one Combi Clas System one |
Insufficient circulation indication |
D.H.W Circuit | ||
202 | Clas HE evo Clas he evo system E-combi evo E-system evo |
2 bottom storage temperature probe open/short circuit |
204 | Clas HE evo Clas he evo system E-combi evo E-system evo |
Solar collector temperature probe open/short circuit |
205 | E-combi one E-System one Clas Net one Combi Clas one Combi |
Domestic hot water in probe open circuit |
207 | Clas HE evo Clas he evo system E-combi evo E-system evo |
Solar collector overheating |
208 | Clas HE evo Clas he evo system E-combi evo E-system evo |
Collector frost protection temperature |
Internal printed circuit board (PCB) | ||
301 | All Boilers | EEPROM error |
302 | All Boilers | Communication error |
303 | All Boilers | Main printed circuit board (PCB) error |
304 | All Boilers | Too many resets (> 5) in 15 minutes |
305 | All Boilers | Main printed circuit board (PCB) error |
306 | All Boilers | Main printed circuit board (PCB) error |
307 | All Boilers | Main printed circuit board (PCB) error |
3P9 | E-combi one E-System one Clas Net one Combi Clas one Combi Clas System one |
Schedule service |
External printed circuit board (PCB) | ||
407 | Clas HE evo Clas he evo system E-combi evo E-system evo |
7 Room sensor circuit open/short circuit |
Ignition and Detection | ||
501 | All Boilers | No flame detected |
502 | All Boilers | Flame detected with gas valve closed |
504 | All Boilers | Flame lift |
5P1 | All Boilers | 1st ignition failed |
5P2 | All boilers | 2nd ignition failed |
5P3 | All Boilers | Flame cut-of |
Air Inlet / Flue gas outlet | ||
604 | CLAS HE R E-Combi Evo E-System EVO Clas HE evo Combi Clas HE evo System |
Insufficient fan speed |
610 | All Boilers | Thermofuse open |
612 | Clas HE Evo Combi Clas He Evo System E-Combi Evo E-system Evo Clas net one combi Clas one combi Clas system one |
Fan speed has incorrect measurement |
Multi-zone Heating | ||
701 | E-Combi Evo E-System EVO Clas HE evo combi Clas he evo system |
Zone 2 outgoing sensor defective |
702 | E-Combi Evo E-System EVO Clas HE evo Combi Clas HE evo System |
Zone 2 return sensor defective |
703 | E-Combi Evo E-System EVO Clas HE evo combi Clas he evo system |
Zone 3 outgoing sensor defective |
704 | E-Combi Evo E-System EVO Clas HE evo Combi Clas HE evo System |
Zone 3 return sensor defective |
705 | E-Combi Evo E-System EVO Clas HE evo combi Clas he evo system |
Hydraulic separation sensor defective |
706 | E-Combi Evo E-System EVO Clas HE evo combi Clas he evo system |
Zone 2 overheating |
707 | E-Combi Evo E-System EVO Clas HE evo Combi Clas HE evo System |
Zone 3 overheating |
Fault Code | Possible Cause |
---|---|
External printed circuit board (PCB) | |
411 | Room sensor circuit open or short circuit zone 1 |
412 | Room sensor circuit open or short circuit zone 2 |
414 | Room sensor circuit open or short circuit zone 3 |
Multi-zone Heating | |
701 | Send sensor defective (Zone 1) |
702 | Send sensor defective (Zone 2) |
703 | Send sensor defective (Zone 3) |
711 | Return sensor defective (zone 1) |
712 | Return sensor defective (zone 2) |
713 | Return sensor defective (zone 3) |
722 | Overheating in zone 2 |
723 | Overheating in zone 3 |
750 | All heating zones locked |
By using this website, you agree to our use of anonymous cookies