| Fault Code | Possible Cause |
|---|
| E09 |
Gas valve connection cable fault |
| E10 |
External probe fault |
| E12 |
Differential water flow switch is still open |
| E13 |
Differential water flow switch is still closed |
| E15 |
Fault with the gas valve command |
| E20 |
Central heating negative temperature coefficient (NTC) fault |
| E28 |
Flue negative temperature coefficient (NTC) fault |
| E40 |
Central heating return negative temperature coefficient (NTC) fault |
| E50 |
Domestic hot water (DHW) negative temperature coefficient (NTC) sensor (tank boiler) (s.c) or DHW NTC sensor (tank boiler) (o.c.) Fault |
| E83 / E84 / E85 / E86 / E87 |
Communication error |
| E109 |
Pre-circulation fault |
| E110 |
Boiler Max temperature exceeded for gradient (or overtemperature) Probable pump jammed or air in the circuit or Safety thermostat sensor tripped |
| E118 |
Primary system water pressure too low |
| E125 |
Primary circulation fault |
| E128 |
Flame failure (12 times) |
| E129 |
Frequent loss of flame (safety error ) |
| E130 |
Flue thermostat sensor tripped and locked out |
| E133 |
Possible gas supply issue (failure to light) |
| E134 |
Elapsed time gas valve open without gas |
| E135 |
Internal error (interruption of gas supply) |
| E154 |
Flow/return sensor temperature test |
| E160 |
Problem with fan (possible wiring fault) |
| E163 |
Domestic hot water (DHW) negative temperature coefficient (NTC) sensor fault (s.c.) or DHW NTC sensor fault (o.c.) |
| E270 |
Dry fire |
| E317 |
Wrong power supply (HZ) |
| E321 |
Hot water fault |
| E384 |
False flame |
| E385 |
Under voltage |
| E430 |
Water pressure test |
| E430 + Flame crossed |
Water pressure test failed |